Pall Supor EKV Cross-Reference

Home / Cross-Reference / Pall / Supor EKV
Competitor Part · Pall Ultrafilter Replacement Pharma
Switching from
Pall Supor EKV?

Not every Pall Supor EKV configuration has an exact Ultrafilter match. Our filtration experts review your part number and application and recommend the right replacement.

What it is: Hydrophilic PES membrane in Pall's patented Ultipleat laid-over-pleat geometry with built-in asymmetric prefilter layer. 0.2 µm sterilizing grade, validated by B. diminuta liquid challenge at ≥10⁷ CFU/cm². Every cartridge integrity-tested, lot/serial numbered, supplied with CoT covering USP Class VI plastics, USP <788> particulates, USP endotoxins (<0.25 EU/mL).

Use for: Final sterile filtration of buffers, cell culture media, biological process fluids, high-value preparations where maximum active-ingredient transmission matters.

Talk to a filtration expert  →

Response within one business day · No obligation

Ultrafilter · replacement on expert recommendation
10
Part numbers listed
On request
Ultrafilter replacement
Pharma
Application grade
On request
Validation documentation
Part number cross-reference

Point for point.

10 Pall part numbers listed. Ultrafilter replacement on request — talk to a filtration expert. Pall values from published datasheets.

Part Numbers Length Rating Adapter Seal
Pall SKU Ultrafilter SKU Competitor UF Code Competitor UF Code Competitor UF Code Competitor UF Code
AB05EKV2PH4 Talk to an expert → 127 mm (5") — 0.2 µm sterilizing — SOE flat closed end, 226 O-rings — Silicone Elastomer —
AB05EKV2PJ Talk to an expert → 127 mm (5") — 0.2 µm sterilizing — SOE flat closed end, 226 O-rings — Ethylene Propylene Rubber —
AB05EKV7PH4 Talk to an expert → 127 mm (5") — 0.2 µm sterilizing — SOE fin end, 226 O-rings, 2 locking tabs — Silicone Elastomer —
AB05EKV7PJ Talk to an expert → 127 mm (5") — 0.2 µm sterilizing — SOE fin end, 226 O-rings, 2 locking tabs — Ethylene Propylene Rubber —
AB1EKV7PH4 Talk to an expert → 254 mm (10") — 0.2 µm sterilizing — SOE fin end, 226 O-rings, 2 locking tabs — Silicone Elastomer —
AB1EKV7PJ Talk to an expert → 254 mm (10") — 0.2 µm sterilizing — SOE fin end, 226 O-rings, 2 locking tabs — Ethylene Propylene Rubber —
AB2EKV7PH4 Talk to an expert → 508 mm (20") — 0.2 µm sterilizing — SOE fin end, 226 O-rings, 2 locking tabs — Silicone Elastomer —
AB2EKV7PJ Talk to an expert → 508 mm (20") — 0.2 µm sterilizing — SOE fin end, 226 O-rings, 2 locking tabs — Ethylene Propylene Rubber —
AB3EKV7PH4 Talk to an expert → 762 mm (30") — 0.2 µm sterilizing — SOE fin end, 226 O-rings, 2 locking tabs — Silicone Elastomer —
AB3EKV7PJ Talk to an expert → 762 mm (30") — 0.2 µm sterilizing — SOE fin end, 226 O-rings, 2 locking tabs — Ethylene Propylene Rubber —
10 part numbers listed · Ultrafilter replacement on request
Technical note

Intended use.

Technical guidance only

Verify fitness for your specific application and regulatory context before qualifying any replacement.

Technical Documents
Datasheet Supor EKV Datasheet
Published by Pall · opens in new tab
Why switch

Expert recommendation.
Built in Germany.

01 · Expert review

No blind swaps.

Our filtration experts compare your Pall Supor EKV with the Ultrafilter range and recommend the element that fits your application.

02 · Expert support

No part number listed?

For part numbers marked “Talk to an expert”, our filtration engineers recommend the right Ultrafilter element for your housing and application.

03 · European supply chain

German manufacturing. Direct access.

Manufactured in Germany. Direct technical support, application-specific configuration, and rapid re-supply for critical filtration lines.

Ready to switch?

Talk to a
filtration expert.

Send us your Pall part number. We will recommend the right Ultrafilter replacement, spec sheet, and pricing within one business day.

Cross-reference note

Pall Supor EKV is a product of Pall Corporation. Pall is a registered trademark of Pall Corporation. Ultrafilter GmbH has no affiliation with Pall Corporation. This cross-reference is provided as technical guidance only. Verify fitness for your specific application and regulatory context before qualifying any replacement.